0 Review(s)

| Model | 0.7K | 1K | 1.5K | 2K | 2.5K | 3K | 3.6K |
|---|---|---|---|---|---|---|---|
| DC Input | |||||||
| Recommended Max. PV Power | 1.1 kW | 1.5 kW | 2.3 kW | 3 kW | 3.8 kW | 4.5 kW | 5.4 kW |
| Max. Input Voltage | 600 V | ||||||
| Nominal Voltage | 200 V | 330 V | |||||
| Starting Voltage | 60 V | 90 V | |||||
| MPPT Voltage Range | 50–500 V | 80–500 V | |||||
| Max. Input Current | 14 A | 19 A | |||||
| Max. Short Circuit Current | 22 A | 24 A | |||||
| No. of MPPTs / Max. Input Strings per MPPT | 1 / 1 | 1 / 2 | |||||
| AC Output | |||||||
| Nominal Output Power | 0.7 kW | 1 kW | 1.5 kW | 2 kW | 2.5 kW | 3 kW | 3.6 kW |
| Nominal Apparent Power | 0.77 kVA | 1.1 kVA | 1.65 kVA | 2.2 kVA | 2.75 kVA | 3.3 kVA | 3.6 kVA |
| Max. Output Power | 0.77 kW | 1.1 kW | 1.65 kW | 2.2 kW | 2.75 kW | 3.3 kW | 3.6 kW |
| Nominal Grid Voltage | 1/N/PE, 220 V / 230 V | ||||||
| Nominal Grid Frequency | 50 Hz / 60 Hz | ||||||
| Nominal Output Current | 3.2 A / 3.0 A | 4.5 A / 4.3 A | 6.8 A / 6.5 A | 9.1 A / 8.7 A | 11.4 A / 10.9 A | 13.6 A / 13 A | 16 A |
| Max. Output Current | 4.4 A | 5.2 A | 8.1 A | 10.5 A | 13.3 A | 15.7 A | 16 A |
| Power Factor | >0.99 (adjustable from 0.8 leading to 0.8 lagging) | ||||||
| THDi | <3% | ||||||
| Efficiency | |||||||
| Max. Efficiency | 96.6% | 96.6% | 97.1% | 97.1% | 97.3% | ||
| European Efficiency | 95.3% | 95.4% | 96.6% | 96.6% | 96.8% | ||
| Protection | |||||||
| DC Reverse Polarity Protection | Yes | ||||||
| Short Circuit Protection | Yes | ||||||
| Output Overcurrent Protection | Yes | ||||||
| Surge Protection | Yes | ||||||
| Grid Monitoring | Yes | ||||||
| Anti-islanding Protection | Yes | ||||||
| Temperature Protection | Yes | ||||||
| Integrated AFCI (DC Arc Fault Protection) | Yes (¹ Activation required) | ||||||
| Integrated DC Switch | Optional | ||||||
| General Data | |||||||
| Dimensions (W × H × D) | 310 × 373 × 160 mm | ||||||
| Weight | 7.4 kg | 7.7 kg | |||||
| Topology | Transformerless | ||||||
| Self-consumption (night) | <1 W | ||||||
| Operating Temperature Range | –25 °C ~ +60 °C | ||||||
| Relative Humidity | 0 – 100% | ||||||
| Ingress Protection Rating | IP66 | ||||||
| Cooling Concept | Natural Cooling | ||||||
| Max. Operating Altitude | 4000 m | ||||||
| Grid Connection Standard | G98 or G99, VDE-AR-N 4105/VDE 0124, EN 50549-1, VDE 0126/UTE C15/FR:2019, RD 1699/RD 244/UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, IOR, EIFS 2018.2, IEC 62116, CEI 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA | ||||||
| Safety / EMC Standard | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4 | ||||||
| Features | |||||||
| DC Connection | MC4 Connector | ||||||
| AC Connection | Quick Connection Plug | ||||||
| Display | LCD | ||||||
| Communication | RS485, Optional: Wi-Fi, GPRS | ||||||