0 Review(s)
Model | SUN-7K-G02P1-EU-AM2 | SUN-7.5K-G02P1-EU-AM2 | SUN-8K-G02P1-EU-AM2 |
---|---|---|---|
PV String Input Data | |||
Max. PV Input Power (kW) | 10.5 | 11.3 | 12 |
Max. PV Input Voltage (V) | 550 | ||
Start-up Voltage (V) | 80 | ||
MPPT Voltage Range (V) | 70–500 | ||
Rated PV Input Voltage (V) | 360 | ||
Max. Operating PV Input Current (A) | 18+26 | ||
Max. Input Short Circuit Current (A) | 27+39 | ||
No. of MPPT Trackers / No. of Strings per MPPT | 2 / 1+2 | ||
AC Output Side | |||
Rated AC Output Active Power (kW) | 7 | 7.5 | 8 |
Max. AC Output Apparent Power (kVA) | 7.7 | 8.25 | 8.8 |
Rated AC Output Current (A) | 31.9 / 30.5 | 34.1 / 32.7 | 36.4 / 34.8 |
Max. AC Output Current (A) | 35 / 33.5 | 37.5 / 35.9 | 40 / 38.3 |
Rated Output Voltage / Range (V) | 220 / 230 ±0.85Un–1.1Un | ||
Grid Connection Form | L / N / PE | ||
Rated Output Grid Frequency / Range (Hz) | 50 / 45–55, 60 / 55–65 | ||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||
Total Current Harmonic Distortion THDi | <3% | ||
DC Injection Current | <0.5%In | ||
Efficiency | |||
Max. Efficiency | 97.7% | ||
Euro Efficiency | 97.2% | ||
MPPT Efficiency | >99% | ||
Equipment Protection | |||
DC Polarity Reverse Connection Protection | Yes | ||
AC Output Overcurrent Protection | Yes | ||
AC Output Overvoltage Protection | Yes | ||
AC Output Short Circuit Protection | Yes | ||
Thermal Protection | Yes | ||
DC Terminal Insulation Impedance Monitoring | Yes | ||
DC Component Monitoring | Yes | ||
Ground Fault Current Monitoring | Yes | ||
Arc Fault Circuit Interrupter (AFCI) | Optional | ||
Power Network Monitoring | Yes | ||
Island Protection Monitoring | Yes | ||
Earth Fault Detection | Yes | ||
Overvoltage Load Drop Protection | Yes | ||
Residual Current (RCD) Detection | Yes | ||
Surge Protection Level | TYPE II (DC), TYPE II (AC) | ||
Interface | |||
Communication Interface | RS485 / RS232 | ||
Monitor Mode | GPRS / WiFi / Bluetooth / 4G / LAN (Optional) | ||
General Data | |||
Operating Temperature Range (°C) | –25 to +60°C, >45°C Derating | ||
Permissible Ambient Humidity | 0–100% | ||
Permissible Altitude (m) | 3000 | ||
Noise (dB) | <35 | ||
Ingress Protection (IP) | IP65 | ||
Inverter Topology | Non-Isolated | ||
Over Voltage Category | OVC II (DC), OVC III (AC) | ||
Cabinet Size (W×H×D mm) | 330 × 310 × 208.5 (Excluding Connectors and Brackets) | ||
Weight (kg) | 12.1 | ||
Warranty | 5 Years | ||
Type of Cooling | Natural Cooling | ||
Grid Regulation | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | ||
Safety EMC / Standard | IEC / EN 61000-6-1 / 2 / 3 / 4, IEC / EN 62109-1, IEC / EN 62109-2 |