Model | SUN-3K-G05 | SUN-4K-G05 | SUN-5K-G05 | SUN-6K-G05 | SUN-7K-G05 | SUN-8K-G05 | SUN-9K-G05 | SUN-10K-G05 | SUN-12K-G05 | SUN-15K-G05 |
---|---|---|---|---|---|---|---|---|---|---|
PV String Input Data | ||||||||||
Max. PV Input Power (kW) | 4.5 | 6 | 7.5 | 9 | 10.5 | 12 | 13.5 | 15 | 18 | 22.5 |
Max. PV Input Voltage (V) | 1100 | |||||||||
Start-up Voltage (V) | 140 | |||||||||
MPPT Voltage Range (V) | 120–1000 | |||||||||
Rated PV Input Voltage (V) | 600 | |||||||||
Max. Operating PV Input Current (A) | 20+20 | 20+26 | ||||||||
Max. Input Short Circuit Current (A) | 30+30 | 30+39 | ||||||||
No. of MPPT Trackers / Strings per MPPT | 2 / 1+1 | 2 / 1+2 | ||||||||
AC Output Side | ||||||||||
Rated AC Output Active Power (kW) | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 12 | 15 |
Max. AC Output Apparent Power (kVA) | 3.3 | 4.4 | 5.5 | 6.6 | 7.7 | 8.8 | 9.9 | 11 | 13.2 | 16.5 |
Rated AC Output Current (A) | 4.6 / 4.4 | 6.1 / 5.8 | 7.6 / 7.3 | 9.1 / 8.7 | 10.7 / 10.2 | 12.2 / 11.6 | 13.7 / 13.1 | 15.2 / 14.5 | 18.2 / 17.4 | 22.8 / 21.8 |
Max. AC Output Current (A) | 5 / 4.8 | 6.7 / 6.4 | 8.4 / 8 | 10 / 9.6 | 11.7 / 11.2 | 13.4 / 12.8 | 15 / 14.4 | 16.7 / 16 | 20 / 19.2 | 25 / 24 |
Rated Output Voltage / Range (V) | 220 / 380V, 230 / 400V, 0.85Un–1.1Un | |||||||||
Grid Connection Form | 3L / N / PE | |||||||||
Rated Output Grid Frequency / Range (Hz) | 50 / 45–55, 60 / 55–65 | |||||||||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |||||||||
Total Current Harmonic Distortion THDi | <3% | |||||||||
DC Injection Current | <0.5%In | |||||||||
Efficiency | ||||||||||
Max. Efficiency | 98.1% – 98.5% | |||||||||
Euro Efficiency | 97.5% – 98% | |||||||||
MPPT Efficiency | >99% | |||||||||
Equipment Protection | ||||||||||
DC Polarity Reverse Connection Protection | Yes | |||||||||
AC Output Overcurrent Protection | Yes | |||||||||
AC Output Overvoltage Protection | Yes | |||||||||
AC Output Short Circuit Protection | Yes | |||||||||
Thermal Protection | Yes | |||||||||
DC Terminal Insulation Impedance Monitoring | Yes | |||||||||
DC Component Monitoring | Yes | |||||||||
Ground Fault Current Monitoring | Yes | |||||||||
Arc Fault Circuit Interrupter (AFCI) | Optional | |||||||||
Power Network Monitoring | Yes | |||||||||
Island Protection Monitoring | Yes | |||||||||
Earth Fault Detection | Yes | |||||||||
Overvoltage Load Drop Protection | Yes | |||||||||
Residual Current (RCD) Detection | Yes | |||||||||
Surge Protection Level | TYPE II (DC), TYPE II (AC) | |||||||||
Interface | ||||||||||
Communication Interface | RS485 / RS232 | |||||||||
Monitor Mode | GPRS / WiFi / Bluetooth / 4G / LAN (Optional) | |||||||||
General Data | ||||||||||
Operating Temperature Range (°C) | –25 to +60°C, >45°C Derating | |||||||||
Permissible Ambient Humidity | 0–100% | |||||||||
Permissible Altitude (m) | 4000 | |||||||||
Noise (dB) | <45 | |||||||||
Ingress Protection (IP) | IP65 | |||||||||
Inverter Topology | Non-Isolated | |||||||||
Over Voltage Category | OVC II (DC), OVC III (AC) | |||||||||
Cabinet Size (W×H×D mm) | 283 × 463 × 178 (Excluding Connectors and Brackets) | |||||||||
Weight (kg) | 11 | |||||||||
Warranty | 5 Years | |||||||||
Type of Cooling | Natural Cooling | |||||||||
Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, ÖVE-Richtlinie R25, G99, VDE-AR-N 4105 | |||||||||
Safety / EMC Standard | IEC / EN 61000-6-1 / 2 / 3 / 4, IEC / EN 62109-1, IEC / EN 62109-2 |